After-sales
Dental Lab Remake Request Guide
What to send, how to describe a problem and how a remake review actually reaches a decision — written so the exchange takes one message instead of five.
A remake request is a request for a decision. The faster the review can reach one, the sooner the case is resolved and the patient is out of limbo. This guide covers what to send, how to describe the problem, and how a laboratory review actually works its way to a conclusion — so the exchange takes one round of messages rather than five.
The formal process, including the boundaries of what is covered and who carries the cost, is on the remake and issue review policy page. This guide is the practical companion: what goes in the message.
Why the quality of the request determines the speed of the answer
A review needs to answer one question: did the restoration match the confirmed requirement, and if not, why? Everything a review does is in service of that question. A request that supplies the confirmed requirement clearly, shows the problem clearly, and says what has already been done to the restoration lets the review answer the question in a single pass.
A request that says “the crown does not fit” forces the review to reconstruct requirements from scratch, ask for photographs, ask whether anything was adjusted, and then start. The technical work is the same; the elapsed time is not.
What to send
1. The original prescription and any standing instructions
Send the prescription as submitted: tooth number, restoration type, material, shade with its shade-guide system, implant system and connection where applicable, and any special instructions for that case. If the case ran against standing instructions held on file, reference them so the review uses the same standard the production team used.
Most remake questions resolve faster when the original intent is unambiguous. A review cannot assess “does it match?” without the “it” being defined.
2. A precise description of the problem
State what you observed, in clinical terms, with a location and, where relevant, a magnitude. The difference in review speed is substantial:
| Slower to act on | Faster to act on |
|---|---|
| “The crown does not fit.” | “The unit rocks on the die; the distal margin is open by roughly 0.3 mm, the mesial seats fully.” |
| “The colour is wrong.” | “Body shade reads A3 against the A2 prescription; the incisal is correct.” |
| “The bite is high.” | “Heavy occlusal contact on the distobuccal cusp; the patient cannot fully close.” |
| “The contact is off.” | “The mesial contact is open; floss passes with no resistance.” |
A description that names the surface, the direction and the magnitude can be checked directly against the production record. A general statement cannot.
3. Photographs
Visual evidence is often what turns a description into a diagnosis. Where practicable, send:
- the restoration seated in the mouth, in focus, with the problem area visible;
- the problem itself at magnification — the open margin, the contact, the fracture line;
- the restoration off the model or die, showing the fit surface;
- the opposing dentition and any articulating marks, if occlusion is the issue;
- an untreated pre-operative view where the case allows it.
How to take these usefully, including why lighting and a reference in frame matter, is covered in what a dental lab can and cannot tell from a photo.
4. The original records
Send the original scan files, model, bite registration and opposing arch information. For a digital case, resending the files is usually the fastest route, because it lets the review open the case in the same software the design was made in. For a conventional case, returning the model or die lets the fit be assessed directly rather than from a photograph.
5. A note on any clinical adjustment already made
If the restoration was adjusted in the mouth, say so and describe what was adjusted and how much. This matters for two reasons: it changes what can still be assessed, and it affects whether the original finding can be attributed. An undisclosed adjustment can make a straightforward review ambiguous.
6. A case reference, not a patient identifier
Use the anonymous case reference. Do not send patient names, patient identifiers or identifiable clinical photographs. The Privacy Policy explains what we ask you not to send and why.
What happens after you send it
The review examines four things together, because a single element rarely explains an issue on its own:
- The prescription and submitted records — what was asked for, and whether the supplied records were complete and unambiguous.
- The submitted files or physical records — scan quality, margin capture, bite data, implant component information and preparation space.
- The production record — the workflow used, the checkpoints passed and the recorded outcome of each.
- The finished restoration — the physical or photographic evidence of the reported problem.
The finding is then sorted into one of three outcomes, which is where the question of responsibility and cost is settled. That breakdown, and the escalation route if you disagree with the outcome, is set out in full in the remake and issue review policy.
Common causes, and what they tell you
Understanding the likely cause helps you describe the problem and set expectations:
| Reported issue | Common causes | Where the fix lies |
|---|---|---|
| Open margin | Scan under-capture at the margin; margin damage in transit; preparation finish line unclear | Rescan, or review the finish line |
| High occlusion | Bite record captured in the wrong position; record deformed; insufficient clearance | Re-take the record, or review the reduction |
| Open or tight contact | Contact designed to the scan but the scan did not fully capture the proximal surface; adjacent tooth position changed since scanning | Review the scan data and the case timeline |
| Shade mismatch | Written shade and photographic target in conflict; lab lighting vs chair lighting | Align the prescribed shade with the target photo |
| Fracture | Insufficient material thickness in a load-bearing area; connector too thin; bruxing load higher than assumed | Review the reduction and the occlusal scheme |
| Damage on arrival | Transit impact or movement inside the packaging | Courier claim, plus a case-level review |
Notice how many of these trace upstream to the scan, the record or the preparation. That is the normal distribution — and it is why the review examines the submitted information as closely as the finished unit.
How to reduce the number of requests
The remake rate is largely set before production starts. The levers, in order of impact, are covered in how to reduce dental remakes — but the summary is: margin visibility at the scan, an accurate bite record, adequate reduction, and unambiguous instructions. Each of those is cheaper than a remake.
Related reading
- Remake and issue review policy — the formal process, responsibility and cost.
- What a dental lab can and cannot tell from a photo — how to document a problem visually.
- Inside a dental lab quality check — what was checked before the unit shipped.
- Case communication standards — how to describe a case or a problem without ambiguity.